=Remaining ballroom-specific Fire code to-do's =
=Remaining code-compliance work to ballroom=
*1. More new electrical EMT conduit & wire pulled to:  
*1. More new electrical EMT conduit & wire pulled to:  
** Ballroom mezzanine, above top landing of SE staircase (Shattuck-side) from ballroom floor, for
** Ballroom mezzanine, above top landing of SE staircase (Shattuck-side) from ballroom floor, for

Revision as of 09:24, 4 January 2015

This page represents a list of work to be done on the Omni Commons ballroom specifically (not the whole building).

  • It is a work in progress.

Overview

  • The ballroom represents the greatest potential income resource for the Commons in terms of event rentals. The sooner the physical infrastructure in the ballroom is brought up to code, and the A/V production infrastructure improved / professionalized, the more rentable the room and therefore the more financially secure the Omni Commons as a whole will be. This document intends to provide an overview of the work remaining to be done.
  • An astounding amount of physical work was done on the ballroom from August-September 2014. Core ballroom volunteers were from Sudo Room, FNB, CCL, and BAPS. Shout-outs to Sean L., Maximillian (FNB), Mary W., TJ, Oskar, Rhodey, Ben B., Patrik D. After a spending-freeze-induced hiatus, beginning in Jan 2015 work will be continued in the ballroom in order to make it rentable.
  • To facilitate participation and focus volunteer effort, ballroom work can be divided into two tiers:
    • Building code compliance and use permit-related physical construction and improvements. Examples:
      • Fire Prevention Life & Safety Code Compliance: Installing Exit signs, emergency lighting, extinguishers, panic bars, etc
      • Use permit conditions: Fabricating Soundproofing for roof skylights.
    • Production-related audio / visual enhancements:
      • Active acoustics: ballroom infrastructure for Sound Amplification, Mixing, Recording
      • Passive acoustics: installing Sound diffusion (echo reduction)
      • Lighting


Remaining code-compliance work to ballroom

  • 1. More new electrical EMT conduit & wire pulled to:
    • Ballroom mezzanine, above top landing of SE staircase (Shattuck-side) from ballroom floor, for
      • Emergency Exit Sign w/ integrated emergency lighting, and
      • a permanent light w/ switch, to illuminate the dark staircase
  • 2. Modern exit sign fixtures w/ integrated emergency lighting ('bug eyes') installed to:
    • Above the double-doors opening to the street on Shattuck, leading to the ballroom
    • Ballroom mezzanine, above top landing of SE (Shattuck-side) staircase from ballroom floor.
  • 3. Tagged, current Class-ABC 5lb Fire extinguishers installed to:
    • Ballroom Mezzanine, near top landing of SE (sSattuck-side) staircase from ballroom floor
    • Ballroom Mezzanine, near top landing of SW (stage-side) staircase to ballroom floor
    • Near NW exit from ballroom, ie towards rear of cafe
  • 4a. Panic bars installed to the following doors:
    • Both sets of ballroom double-doors leading to Shattuck on East side
    • Double-doors on NE corner of ballroom leading to cafe
    • Single wide door on NW corner of ballroom leading to back of cafe
  • 4b. Panic-bar-friendly access control / locks installed to:
    • Both sets of ballroom double-doors leading to Shattuck on East side
    • Double-doors on NE corner of ballroom leading to cafe
    • Single wide door on NW corner of ballroom leading to back of cafe
  • 5. Door-closers installed atop all main doors to ballroom, including:
    • NE double-doors to Cafe
    • NW large door: from Cafe (this is technically in the cafe, but is the only door.)
    • both sets of double-doors to ballroom's Shattuck entrance
    • SE door to basement