==General==
==General==
Remove all extension cords, replace with conduit or install outlets if necessary
<s>Remove all extension cords, replace with conduit or install outlets if necessary</s> ---> still need to install conduit by 48th St entrance


== Ballroom ==
== Ballroom ==
Line 17: Line 17:
=== Mezzanine ===
=== Mezzanine ===
* SW staircase up: Repair hole in south wall near floor immediately across from stairs (see south wall acoustic treatment)
* SW staircase up: Repair hole in south wall near floor immediately across from stairs (see south wall acoustic treatment)
* SW & SE staircases: motion detectors up & down
* <s>SW & SE staircases: motion detectors up & down</s>
* SW & SE staircases: LED strip lighting on each side
* SW & SE staircases: LED strip lighting on each side


Line 23: Line 23:
* outlet needs to be replaced with GFCI - Note: no ground; Gerald suggests decommissioning and installing new grounded plug in wall just above counter; go into wall from other side, need to locate grounded location
* outlet needs to be replaced with GFCI - Note: no ground; Gerald suggests decommissioning and installing new grounded plug in wall just above counter; go into wall from other side, need to locate grounded location
* all exposed bulb fixtures need be replaced with covered fixtures (2x)
* all exposed bulb fixtures need be replaced with covered fixtures (2x)
* Install paper towell holder


=== Mezzanine "Book Room" ===
=== Mezzanine "Book Room" ===
Line 29: Line 28:


=== Crow's Nest ===
=== Crow's Nest ===
* Clear everything 3' in front of electrical subpanel including all cords, lighitng, etc
* <s>Clear everything 3' in front of electrical subpanel including all cords, lighitng, etc</s> --> double check periodically
* acquire & install cover for light (fixture takes glass orb / cover around bulb, it is missing)
* acquire & install cover for light (fixture takes glass orb / cover around bulb, it is missing)
* extend balcony railing to out in front of balcony hatch - on E side of R&J balcony (building & osha safety)
* extend balcony railing to out in front of balcony hatch - on E side of R&J balcony (building & osha safety)


=== A/V Room ===
=== A/V Room ===
* Patch small hole above door where conduit is peeking through.
* Patch long thinnish strip above door where conduit is exposed.
* Patch hole near floor in NW corner of this room near door jamb. <--In progress by kkr
* <s>Patch hole near floor in NW corner of this room near door jamb.</s> <--needs another coat but effectively done


=== Ticketbooth Room ===
=== Ticketbooth Room ===
Line 46: Line 45:


=== balcony ===
=== balcony ===
* 4'x2' light fixture panel cover
* 4'x2' light fixture panel cover  
* install paper towel dispenser and paper towels
* bathroom: Replace light fixture (sub-8') with standard caged bell-jar type
* bathroom: Replace light fixture (sub-8') with standard caged bell-jar type
* between fridges: Lock roofer's ladder (that lives b/t fridges in balcony) to wall.  
* between fridges: Lock roofer's ladder (that lives b/t fridges in balcony) to wall.  
* kitchenette: replace CFL bulb in kitchen with 'safe' LED (silicone-wrapped kind) spot shape - e.g. for food safety if CFL breaks
* <s>kitchenette: replace CFL bulb in kitchen with 'safe' LED (silicone-wrapped kind) spot shape - e.g. for food safety if CFL breaks http://www.homedepot.com/p/Philips-60W-Equivalent-Soft-White-A19-A-Line-Spiral-CFL-Light-Bulb-2-Pack-E-434357/203001435</s>


=== TIL ===
=== TIL ===
Line 57: Line 55:


== Basement ==
== Basement ==
* south wall: close holes in basement wall where opened to remove mold.
* south wall: close holes in basement wall where opened to remove mold.
* Phat Beets room ventilation doesn't work. people can suffocate in there.
* LibLens room ventilation doesn't work. people can suffocate in there.
* repair red stage
* <s>clear remaining junk</s>
* clear remaining junk


=== ceiling ===
=== ceiling ===
* Acquire & install light fixture covers for the 4' flourescent fixtures in basement offices (bunker rooms) - roughly ~48"x16".  
* Acquire & install light fixture covers for the 4' flourescent fixtures in basement offices (bunker rooms) - roughly ~48"x16".  
* install protective bulb covers over remaining working 8' flourescents: 6x
* install protective bulb covers over remaining working 8' flourescents: 6x
* unscrew piece of broken lightbulb from East basement hallway, replace bare-bulb fixture with covered fixture
* replace bare-bulb fixture with covered fixture
* re-attach and restore service to entire strip of 8' flourescents along west wall (closest to sudo) that had been decommissioned
* re-attach and restore service to entire strip of 8' flourescents along west wall (closest to sudo) that had been decommissioned
* acquire and affix 1'x1' ceiling tiles in NW corner of basement, so lighting fixture & strip of lights can be re-connected. ~120 tiles
* acquire and affix 1'x1' ceiling tiles in NW corner of basement, so lighting fixture & strip of lights can be re-connected. ~120 tiles
Line 74: Line 70:
== Bocce Court ==
== Bocce Court ==
* hallway: install paper towel dispenser and paper towels
* hallway: install paper towel dispenser and paper towels
* entire room perimeter - 5LB ABC fire extinguishers at correct height every ~75' - starting w under each exit sign
* <s>entire room perimeter - 5LB ABC fire extinguishers at correct height every ~75' - starting w under each exit sign</s>


===  Sudo ===
===  Sudo ===
* created dedicated space for storing excess lumber (long pieces), pipe, metal pieces, etc so they are not in jumbles (fire code).
* <s>created dedicated space for storing excess lumber (long pieces), pipe, metal pieces, etc so they are not in jumbles (fire code). </s>
* west wall - run more 3/4" conduit further down west wall. Must know code.
* west wall - run more 3/4" conduit further down west wall. Must know code.


=== CCL ===
=== CCL ===
* run new conduit / circuits to reduce excessive extension cord usage (fire code)
* <s>run new conduit / circuits to reduce excessive extension cord usage (fire code)</s>
* west closet: clean up & seal west wall
* west closet: clean up & seal west wall
* west closet: put bulb covers over the 2x 4' flourescents
* west closet: put bulb covers over the 2x 4' flourescents
Line 91: Line 87:
== Disco Room ==
== Disco Room ==
* light switch cover near 48th street door should be replaced by one with less-sharp edges (better-sized)
* light switch cover near 48th street door should be replaced by one with less-sharp edges (better-sized)
* giant lateral file cabinet needs to be removed / find a better home somewhere JOHN GIVENS TO REMOVE - email photo
* <s>giant lateral file cabinet needs to be removed / find a better home somewhere JOHN GIVENS TO REMOVE - email photo</s>
* Trace & label ALL elec outlets in this room
* Trace & label ALL elec outlets in this room
* A/V instructions need to be made for home stereo / speaker setup, mixer in crows nest etc. in this room
* A/V instructions need to be made for home stereo / speaker setup, mixer in crows nest etc. in this room
Line 100: Line 96:
* hole in wall in west staircase down to 48th needs be covered
* hole in wall in west staircase down to 48th needs be covered
* plate to be installed to cover exposed ceiling wires immediately in front of 48th st street door leading up to disco room
* plate to be installed to cover exposed ceiling wires immediately in front of 48th st street door leading up to disco room
* crow's nest: giant hole in crows nest west wall needs to be a) filled with insulation b) covered (drywall etc)
* crow's nest west wall: exposed electrical wires / fixture needs to be covered (and traced)
* crow's nest west wall: exposed electrical wires / fixture needs to be covered (and traced)


== Rise Above ==
== Phat Beets ==
* replaced busted circuit breaker in every electrial panel (like in the 42 breaker panel) with either working breaker or factory blanks.
* replaced busted circuit breaker in every electrical panel (like in the 42 breaker panel) with either working breaker or factory blanks.
* remove 2x6 on ceiling on south side of room (COORDINATE WITH GABRIELA 1ST - move or cover all her stuff.
* remove 2x6 on ceiling on south side of room (move or cover all PB stuff)
* stage left - install paper towel dispenser and paper towels.


<br /><br /><br /><br /><br />
<br /><br /><br /><br /><br />
Line 112: Line 106:


=== shattuck-ballroom outer ===
=== shattuck-ballroom outer ===
* need panic bars
* <s>need panic bars</s>


=== shattuck-ballroom inner ===
=== shattuck-ballroom inner ===
* needs to be hung, closers, panic bars
* <s>needs to be hung, closers, panic bars</s>


=== cafe-basement (big white door) ===
=== cafe-basement (big white door) ===
Line 128: Line 122:


=== bocce-ballroom ===
=== bocce-ballroom ===
* closer
* <s>closer</s>


=== mezzanine book room ===
=== mezzanine book room ===
* Replace door handle with non-locking handle.
* Replace door handle with non-locking handle.


=== opal ===
=== crows nest ===
* Install real doorknob, remove latch
* <s>Install real doorknob, remove latch</s>


=== rise above ===
=== phat beets ===
* replace locking main door to Rise Above in hallway with twenty minute solid-core (fire-code)
* replace locking main door to Phat Beets in hallway with twenty minute solid-core (fire-code)
* replace 2x hollow-core sliding doors with 20 minutes solid-core sliding doors (fire-code)
* put closer on main door to PB
* put closer on main door to Rise Above


=== Blue Room ===
=== Pink Room ===
* to hallway: closer
* to hallway: closer
* to ballroom: closer
* to ballroom: closer
Line 172: Line 165:
=== Ticketbooth Room ===
=== Ticketbooth Room ===
* Install threshold plate to base of jamb (no more than 1/2" high as per ADA) to cut down on sound from ballroom  
* Install threshold plate to base of jamb (no more than 1/2" high as per ADA) to cut down on sound from ballroom  
* install gaskets to door jambs to cut down on sound. (icarus)
* install gaskets to door jambs to cut down on sound.
* Install door closer
* Install door closer


Line 182: Line 175:
* Cut in mop sink in westmost pantry area
* Cut in mop sink in westmost pantry area
* Acquire and install tankless water heater, check gas line diameter & exhaust ductwork  
* Acquire and install tankless water heater, check gas line diameter & exhaust ductwork  
* Purchase and affix Class-K extinguisher at correct height
* <s>Purchase and affix Class-K extinguisher at correct height</s>
* Cover exposed wiring in FNB locked-pantry ceiling (with e.g. metal plate)
* Cover exposed wiring in FNB locked-pantry ceiling (with e.g. metal plate)
* Install Ansul fire-suppression in hood
* Install Ansul fire-suppression in hood
Line 196: Line 189:


=== Balcony ===
=== Balcony ===
* between fridges: get an exterior outlet plastic cover for 4"x4" outlet box here, so outlets do not get wet if it rains when roof hatch is open
* between fridges: get an exterior outlet plastic cover for 4"x4" outlet box here, so outlets do not get wet if it rains when roof hatch is open
* ~6" high barrier along balcony (to stop drinks etc from being knocked off onto those in cafe)
* ~6" high barrier along balcony (to stop drinks etc from being knocked off onto those in cafe)
Line 205: Line 197:


== Disco Room ==
== Disco Room ==
* test linoleum for asbestos content
* <s>test linoleum for asbestos content</s>
* remove linoleum (may need to hire certified abatement company if asbestos present)
* <s>remove linoleum (may need to hire certified abatement company if asbestos present)</s>
* sand wood floor and seal with water based polyurethane
* sand wood floor and seal with water based polyurethane
* all A/V & musical equipment (including in crow's nest) needs to be recorded (serial #s) and ownership determined
* all A/V & musical equipment (including in crow's nest) needs to be recorded (serial #s) and ownership determined

Revision as of 20:23, 7 August 2017

stuff in the building to fix

General

Remove all extension cords, replace with conduit or install outlets if necessary ---> still need to install conduit by 48th St entrance

Ballroom

Bar

  • Outlets on east/shattuck-side wall need to be: removed, wire-nutted, wrapped in elec tape, covered with blank faceplates. TURN OFF CIRCUIT FIRST. Note: furthest N outlet not disconnected, only outlet in the center of the wall
  • sink needs to have hole/leak repaired (stainless steel), and possibly re-mounted / re-caulked.
    • Need to remove blue masonite tabletop as it is weighing the sink down! Modify and return as actual cabinetry / surface.

Ballroom-Shattuck Exit Area

  • install light cover into flourescent panel (22"x3') - flourescents are 2x 2' bulbs

Mezzanine

  • SW staircase up: Repair hole in south wall near floor immediately across from stairs (see south wall acoustic treatment)
  • SW & SE staircases: motion detectors up & down
  • SW & SE staircases: LED strip lighting on each side

Mezzanine Bathroom

  • outlet needs to be replaced with GFCI - Note: no ground; Gerald suggests decommissioning and installing new grounded plug in wall just above counter; go into wall from other side, need to locate grounded location
  • all exposed bulb fixtures need be replaced with covered fixtures (2x)

Mezzanine "Book Room"

  • 4"x4" Outlets affixed to top of Electrical subpanel must be removed from subpanel, and affixed to balcony (code violation) (3x)

Crow's Nest

  • Clear everything 3' in front of electrical subpanel including all cords, lighitng, etc --> double check periodically
  • acquire & install cover for light (fixture takes glass orb / cover around bulb, it is missing)
  • extend balcony railing to out in front of balcony hatch - on E side of R&J balcony (building & osha safety)

A/V Room

  • Patch long thinnish strip above door where conduit is exposed.
  • Patch hole near floor in NW corner of this room near door jamb. <--needs another coat but effectively done

Ticketbooth Room

  • Patch small hole in ceiling corner above ticket window where new conduit was run.
  • install new outlet (existing is cracked and not attached to wall

Front Area

  • cover floor sink behind front counter area w minimum 3/4" plywood cut out and sealant (trip hazard/health)
  • build secure mailbox

balcony

TIL

  • cover exposed wires in east wall (near bookshelf). can use a plate
  • get clear cover to put over wall switch for old electric timer in wall in big bookshelf unit in south wall of TL

Basement

  • south wall: close holes in basement wall where opened to remove mold.
  • LibLens room ventilation doesn't work. people can suffocate in there.
  • clear remaining junk

ceiling

  • Acquire & install light fixture covers for the 4' flourescent fixtures in basement offices (bunker rooms) - roughly ~48"x16".
  • install protective bulb covers over remaining working 8' flourescents: 6x
  • replace bare-bulb fixture with covered fixture
  • re-attach and restore service to entire strip of 8' flourescents along west wall (closest to sudo) that had been decommissioned
  • acquire and affix 1'x1' ceiling tiles in NW corner of basement, so lighting fixture & strip of lights can be re-connected. ~120 tiles
  • Cut & attach drywall AND then also affix 1'x1' ceiling tiles to exposed ceiling areas in basement (2 areas)
  • Replace bad ballast in any 8' flourescent fixture (that is not turning on. If not sure try lights in it that do work in another fixture.

Bocce Court

  • hallway: install paper towel dispenser and paper towels
  • entire room perimeter - 5LB ABC fire extinguishers at correct height every ~75' - starting w under each exit sign

Sudo

  • created dedicated space for storing excess lumber (long pieces), pipe, metal pieces, etc so they are not in jumbles (fire code).
  • west wall - run more 3/4" conduit further down west wall. Must know code.

CCL

  • run new conduit / circuits to reduce excessive extension cord usage (fire code)
  • west closet: clean up & seal west wall
  • west closet: put bulb covers over the 2x 4' flourescents
  • west closet: put bulb covers over the 2x 4' flourescents in annex/closet
  • west closet: replace ballast in flourescent fixture in this room
  • east closet: cover exposed octogon junction box in ceiling with appropriate octogon plate
  • east closet: replace exposed wiring from new LED fixture to ceiling with armored flex or EMT

Disco Room

  • light switch cover near 48th street door should be replaced by one with less-sharp edges (better-sized)
  • giant lateral file cabinet needs to be removed / find a better home somewhere JOHN GIVENS TO REMOVE - email photo
  • Trace & label ALL elec outlets in this room
  • A/V instructions need to be made for home stereo / speaker setup, mixer in crows nest etc. in this room
  • West exit door (top landing to 48th st staircase) needs be panic bar'd
  • install closer to main (east) door of disco room
  • install closer to west / emergency exit door of disco room
  • remove or permanently mount ALL LARGE UNMOUNTED PLATE GLASS MIRRORS in this room: safety hazard
  • hole in wall in west staircase down to 48th needs be covered
  • plate to be installed to cover exposed ceiling wires immediately in front of 48th st street door leading up to disco room
  • crow's nest west wall: exposed electrical wires / fixture needs to be covered (and traced)

Phat Beets

  • replaced busted circuit breaker in every electrical panel (like in the 42 breaker panel) with either working breaker or factory blanks.
  • remove 2x6 on ceiling on south side of room (move or cover all PB stuff)






Doors

shattuck-ballroom outer

  • need panic bars

shattuck-ballroom inner

  • needs to be hung, closers, panic bars

cafe-basement (big white door)

  • needs closer
  • fix panic bar

bocce hallway

  • needs rehang, closer, panic bar, lock

bocce-basement

  • if possible, put closer on this door (may not be possible)

bocce-ballroom

  • closer

mezzanine book room

  • Replace door handle with non-locking handle.

crows nest

  • Install real doorknob, remove latch

phat beets

  • replace locking main door to Phat Beets in hallway with twenty minute solid-core (fire-code)
  • put closer on main door to PB

Pink Room

  • to hallway: closer
  • to ballroom: closer








Wishlist

Ballroom Area

  • balance ballroom fans

Bar

  • Determine fix for leaking sink in 3-sink (weld?) - southmost sink (on left if you are behind bar)
  • Install floor sink under 3-sink as per health code

Crow's Nest

  • Make main (east) door to this room better fitting / gasketed against all air gaps so it functions for soundproofing
  • rebalance fan
  • ensure balcony hatch is robust enough to support 300lb standing weight
  • Refinish & airgap-seal east wall above loft in this room so room functions as soundproofing / air barrier to exterior of bldg
  • make north door to romeo & juliet balcony airtight (or better fitting) for turning this room into a soundproofing barrier

Mezzanine Bathroom

  • active ventilation needs to be wired & installed (exhaust) in current ventilation window
  • install door stop so the door can be propped open sometimes.

Stage

  • Create wider storage openings under stage. Not insubstantial. See stage storage build plan.

Ticketbooth Room

  • Install threshold plate to base of jamb (no more than 1/2" high as per ADA) to cut down on sound from ballroom
  • install gaskets to door jambs to cut down on sound.
  • Install door closer

Basement

kitchen

  • Resurface kitchen floor, cover with quarry tile, or seal / treat concrete
  • Fix or replace corroded window frames along shattuck
  • Cut in mop sink in westmost pantry area
  • Acquire and install tankless water heater, check gas line diameter & exhaust ductwork
  • Purchase and affix Class-K extinguisher at correct height
  • Cover exposed wiring in FNB locked-pantry ceiling (with e.g. metal plate)
  • Install Ansul fire-suppression in hood
  • Replace entire 4' flourescent light fixture closest to stove (has 1x broken tube holder)
  • Acquire makeup air into kitchen (remove desk fan from duct, replace with something to code - 95% of hood CFM)
  • Put closers on both basement kitchen doors
  • steam clean stove hood
  • Knock out / expand west kitchen wall to next-west supporting pipe
  • Remove firred-out drywall, cover with FRP

Front Area

  • fix broken glass pane in 4th window west of front door in La Commune

Balcony

  • between fridges: get an exterior outlet plastic cover for 4"x4" outlet box here, so outlets do not get wet if it rains when roof hatch is open
  • ~6" high barrier along balcony (to stop drinks etc from being knocked off onto those in cafe)
  • bathroom: install ceiling exhaust fan

TIL

  • Get clear cover to put over wall switch for old electric timer in wall in big bookshelf unit in south wall of TIL

Disco Room

  • test linoleum for asbestos content
  • remove linoleum (may need to hire certified abatement company if asbestos present)
  • sand wood floor and seal with water based polyurethane
  • all A/V & musical equipment (including in crow's nest) needs to be recorded (serial #s) and ownership determined
  • ensure remaining shelving along north wall of disco room is fixed/affixed more safely
  • pendant lights should probably be raised a bit higher up (low priority)
  • pendant light switch(es): consider replacing with dimmers
  • lightswitch cover near 48th st door should be replaced with one with less-sharp edges (better-sized)
  • weight load for high-up triangular shelves in corners to be assessed (julia) to determine if speakers etc can be placed there