Difference between revisions of "Electrical"
(no table of contents - we want to do it fancy) |
(merge ADA) |
||
Line 10: | Line 10: | ||
*** '''[[#Panel AC|Panel AC]]''' (in basement NW Kitchen Pantry, on E wall) | *** '''[[#Panel AC|Panel AC]]''' (in basement NW Kitchen Pantry, on E wall) | ||
*** '''[[#Panel AD|Panel AD]]''' (located upstage left in N corner of W wall of ballroom) | *** '''[[#Panel AD|Panel AD]]''' (located upstage left in N corner of W wall of ballroom) | ||
**** '''[[Panel ADA]]''' (in shower room on E wall) | **** '''[[#Panel ADA|Panel ADA]]''' (in shower room on E wall) | ||
*** '''[[Panel AE]]''' (located in storage room S of stage in N corner of W wall of ballroom) | *** '''[[Panel AE]]''' (located in storage room S of stage in N corner of W wall of ballroom) | ||
** '''[[Panel B]]''' (in Crow's Nest above stage in ballroom) | ** '''[[Panel B]]''' (in Crow's Nest above stage in ballroom) | ||
Line 19: | Line 19: | ||
** '''[[#Panel D|Panel D]]''' (in Rise Above on E wall shared with La Commune) | ** '''[[#Panel D|Panel D]]''' (in Rise Above on E wall shared with La Commune) | ||
'''X''' = Disconnected | |||
==Main Panel== | ==Main Panel== | ||
[[File:Panel-main.jpg|right|thumb|Omni's main electrical panel]] | [[File:Panel-main.jpg|right|thumb|Omni's main electrical panel]] | ||
{| class="wikitable" style="text-align: center;" | {| class="wikitable" style="text-align: center;" | ||
|- | |- | ||
Line 63: | Line 60: | ||
==Panel A== | ==Panel A== | ||
[[File:Panel-a.jpg|right|thumb|Panel A]] | [[File:Panel-a.jpg|right|thumb|Panel A]] | ||
200amps | 200amps | ||
{| class="wikitable" style="text-align: center;" | {| class="wikitable" style="text-align: center;" | ||
|- | |- | ||
Line 123: | Line 116: | ||
==Panel AA== | ==Panel AA== | ||
[[File:Panel-aa.jpg|right|thumb|Panel AA]] | [[File:Panel-aa.jpg|right|thumb|Panel AA]] | ||
{| class="wikitable" style="text-align: center;" | {| class="wikitable" style="text-align: center;" | ||
|- | |- | ||
Line 156: | Line 147: | ||
==Panel AB== | ==Panel AB== | ||
[[File:Panel-ab.jpg|right|thumb|Panel AB]] | [[File:Panel-ab.jpg|right|thumb|Panel AB]] | ||
<br clear=all> | <br clear=all> | ||
==Panel AC== | ==Panel AC== | ||
[[File:Panel-ac.jpg|right|thumb|Panel AC]] | [[File:Panel-ac.jpg|right|thumb|Panel AC]] | ||
<br clear=all> | <br clear=all> | ||
==Panel AD== | ==Panel AD== | ||
[[File:Panel-ad.jpg|right|thumb|Panel AD]] | [[File:Panel-ad.jpg|right|thumb|Panel AD]] | ||
{| class="wikitable" style="text-align: center;" | {| class="wikitable" style="text-align: center;" | ||
|- | |- | ||
Line 190: | Line 175: | ||
==Panel ADA== | ==Panel ADA== | ||
[[File:Panel-ada.jpg|right|thumb|Panel ADA]] | [[File:Panel-ada.jpg|right|thumb|Panel ADA]] | ||
{| class="wikitable" style="text-align: center;" | |||
<br clear=all> | |- | ||
! Label -> !! Breaker # | |||
|- | |||
| Former Hot Hub || 1 | |||
|} <br clear=all> | |||
==Panel AE== | ==Panel AE== |
Revision as of 00:39, 31 January 2018
This page provides a "living document" of the Omni Commons electrical system. It is not necessarily completely accurate, though it strives to be, and is always important to get updated!
Primary Electrical System
- Main Panel (in Rise Above, room E of rear [48th St] exit)
- Panel A (adjacent to main in Rise Above)
- Panel AA (in Rise Above, on E wall adjacent to La Commune)
- Panel AB (in basement next to N staircase)
- Panel AC (in basement NW Kitchen Pantry, on E wall)
- Panel AD (located upstage left in N corner of W wall of ballroom)
- Panel ADA (in shower room on E wall)
- Panel AE (located in storage room S of stage in N corner of W wall of ballroom)
- Panel B (in Crow's Nest above stage in ballroom)
- Panel BA (in rear ballroom balcony near S wall)
- Panel BAA (on N wall of classroom between ballroom and La Commune)
- Panel BAAA (on S wall of la commune by entrance book cashier table)
- Panel BAA (on N wall of classroom between ballroom and La Commune)
- Panel BA (in rear ballroom balcony near S wall)
- Panel C (in Disco Room at base of ladder to DJ booth)
- Panel D (in Rise Above on E wall shared with La Commune)
- Panel A (adjacent to main in Rise Above)
X = Disconnected
Main Panel
Label -> | Breaker # | Breaker # | <- Label |
---|---|---|---|
Panel B & Panel D 200amps | 1 | 2 | |
3 | 4 | ||
Panel A 200amps | 5 | 6 | |
7 | 8 | ||
X | 9 | 10 | Panel C 100amps |
11 | 12 | ||
Storage #5 / Trash Room | 13 | 14 | n/a |
15 | 16 | n/a | |
Storage #5 / Trash Room | 17 | 18 | n/a |
Counter Culture Labs (CCL) Closet |
19 | 20 | n/a |
21 | 22 | n/a | |
n/a | 23 | 24 | n/a |
Panel A
200amps
Label -> | Breaker # | Breaker # | <- Label |
---|---|---|---|
Panel AA (La Commune) | 1 | 21 | Panel AE |
2 | 22 | ||
Panel AB | 3 | 23 | 220V plug (rise above dryer) via Panel AA |
4 | 24 | ||
? Panel AC | 5 | 25 | Panel AD |
6 | 26 | ||
7 | 27 | ||
8 | 28 | ||
9 | 29 | ||
Upstairs (cafe mezzanine) kitchen light / Upstairs (cafe mezzanine) bathroom lights / Exit Sign at top of W cafe mezzanine staircase |
10 | 30 | Sudo Room outlets on South Wall |
X | 11 | 31 | X |
Hood over oven in upstairs kitchenette (cafe mezzanine) / W Wall Kitchenette Outlet (R of sink) / W wall kichenette outlet (Above oven in alcove) |
12 | 32 | |
13 | 33 | ||
14 | 34 | ||
15 | 35 | ||
16 | 36 | X | |
17 | 37 | Blue Classroom S wall outlets | |
2 TIL Office Lights (upstairs) / Front Door Exit Sign / Two Lights on Beam at entrance |
18 | 38 | |
Light fixture and outlets in Blue Classroom alcove on N wall |
19 | 39 | |
Upstairs kitchenette (cafe mezzanine) S wall outlets / W Wall Kitchenette Outlet (L of sink) / N wall kitchenette outlets (at entrance) / Outlets under bar on S Wall of Disco Room near S Wal of Kitchenette |
20 | 40 |
Panel AA
Label -> | Breaker # | Breaker # | <- Label |
---|---|---|---|
6 | 12 | ||
5 | 11 | ||
4 | 10 | ||
3 | 9 | wheelchair bathroom light & outlet | |
2 | 8 | ||
1 | 7 |
Panel AB
Panel AC
Panel AD
Label -> | Breaker # | Breaker # | <- Label |
---|---|---|---|
Counter Culture Labs (CCL) E wall outlets |
2 | 1 | Stage Vanity Lights & NW Ballroom Bathroom Light & NW Bathroom Hallway Light |
Panel ADA (2 x 30A) Former Hot Tub in Mezzanine Shower Room |
4 | 3 | Stage Left Ballroom Floor Outlets |
6 | 5 | Stage Right Ballroom Floor Outlets & Stage Right Outlets | |
8 | 7 | Upstage Center outlet & Stage Left Outlet | |
10 | 9 | Crow's Nest Interior light/fan & SW Ballroom Staircase Light & Ballroom Mop Closet Light & Lights beneath Ballroom Mezzanine | |
SE Ballroom Bathroom Lights | 12 | 11 | GFI outlet (used for screen printing sink in Mezzanine Shower Room) |
Panel ADA
Label -> | Breaker # |
---|---|
Former Hot Hub | 1 |
Panel AE
Panel B
Panel BA
Panel BAA
Panel BAAA
Panel C
I couldn't find this panel to take a picture --yar
Panel D
100 amps
Floorplans
- Panel Tree Diagram
{Placeholder}
- Annotated Floorplan
{Placeholder}
Documentation Protocol
Any building's electrical system is intended to serve the needs of the users of the building in a safe manner. However, we operate within constraints such as the historical developments of the electrical system, regulations, best practices, etc. In order to reduce ambiguity and risk, we must use a consistent documentation protocol throughout the system to understand and share knowledge of historical, current, and future uses.
Naming Convention
- Label the main electrical panel as "MAIN"
- Label the direct sub-panels of the main panel with a letter, e.g. "A", "B".
- Label each sub-panel that is connected to a first-tier sub-panel of the main panel.
- "origin panel letter" + "sub-panel letter" + ... (for each sub-panel add another letter) ...
- e.g. "AA" for the first sub-panel from panel "A"
- e.g. "AAB" for the second sub-panel attached to panel "AA"
- "origin panel letter" + "sub-panel letter" + ... (for each sub-panel add another letter) ...
- For each circuit, label each outlet, switch, and load with:
- the appropriate sub-panel name (described above) + "breaker number"
- e.g. All the outlets in one room that are on the same circuit should be labeled "CA4" meaning the circuit is on breaker 4 on panel CA, which is the first panel originating from panel C that connects to the Main panel.
- the draw on the curcuit
- e.g. 20 amps
- the appropriate sub-panel name (described above) + "breaker number"
Here is the OLD breaker panel diagram
Protocol
- We are especially (not exclusively) updating our electrical system documentation on a room-by-room basis.
- As you work throughout Omni Commons, you should only use the system described above to map the electrical system.
- All other systems will be overridden.
- You can print this page and the building floorplans above in order to document the labeling you make on the actual outlets, panels, etc.
- After labeling and writing on the printed building floorplan, deliver it to any member of the Building Working Group.