Difference between revisions of "ToFix"
Jump to navigation
Jump to search
(went over 2 & 3 on the list, categorized by priority) |
(go through top priority ones) |
||
Line 4: | Line 4: | ||
== Ballroom Area == | == Ballroom Area == | ||
* stage left: install paper towel dispenser and paper towels | |||
=== Bar === | === Bar === | ||
Line 34: | Line 35: | ||
* Remove giant bookshelf and all debris/material from this room. Call Emerson - ask them to get their table back, or are they donating to us ? :) | * Remove giant bookshelf and all debris/material from this room. Call Emerson - ask them to get their table back, or are they donating to us ? :) | ||
* Patch small hole in ceiling corner above ticket window where new conduit was run. | * Patch small hole in ceiling corner above ticket window where new conduit was run. | ||
=== Blue Room === | |||
* Install closer to Blue Room door that opens onto hallway | |||
* Install closer to Blue Room door that opens onto Ballroom Bar | |||
== Disco Room == | == Disco Room == | ||
* light switch cover near 48th street door should be replaced by one with less-sharp edges (better-sized) | * light switch cover near 48th street door should be replaced by one with less-sharp edges (better-sized) | ||
* weight load for high triangular shelves in corners to be assessed (julia) to determine if speakers etc can be placed there | * weight load for high triangular shelves in corners to be assessed (julia) to determine if speakers etc can be placed there | ||
* giant lateral file cabinet needs to be removed / find a better home somewhere JOHN GIVENS TO REMOVE - email photo | |||
* Trace & label ALL elec outlets in this room | |||
* A/V instructions need to be made for home stereo / speaker setup, mixer in crows nest etc. in this room | |||
* West exit door (top landing to 48th st staircase) needs be panic bar'd | |||
* install closer to main (east) door of disco room | |||
* install closer to west / emergency exit door of disco room | |||
* remove or permanently mount ALL LARGE UNMOUNTED PLATE GLASS MIRRORS in this room: safety hazard | |||
* hole in wall in west staircase down to 48th needs be covered | |||
* plate to be installed to cover exposed ceiling wires immediately in front of 48th st street door leading up to disco room | |||
* crow's nest: giant hole in crows nest west wall needs to be a) filled with insulation b) covered (drywall etc) | |||
* crow's nest west wall: exposed electrical wires / fixture needs to be covered (and traced) | |||
== La Commune == | == La Commune == | ||
Line 52: | Line 68: | ||
* stage left - install paper towel dispenser and paper towels. | * stage left - install paper towel dispenser and paper towels. | ||
== Sudo == | == Bocce Room == | ||
* hallway: install paper towel dispenser and paper towels | |||
* entire room perimeter - 5LB ABC fire extinguishers at correct height every ~75' - starting w under each exit sign | |||
* hallway door - install panic hardware & lock to this door | |||
* hallway door - install closer to door | |||
=== Sudo === | |||
* created dedicated space for storing excess lumber (long pieces), pipe, metal pieces, etc so they are not in jumbles (fire code). | * created dedicated space for storing excess lumber (long pieces), pipe, metal pieces, etc so they are not in jumbles (fire code). | ||
* west wall - run more 3/4" conduit further down west wall. Must know code. | * west wall - run more 3/4" conduit further down west wall. Must know code. | ||
* ballroom door - put closer on this door | * ballroom door - put closer on this door | ||
* basement door - if possible, put closer on this door (may not be possible) | * basement door - if possible, put closer on this door (may not be possible) | ||
== | === CCL === | ||
* run new conduit / circuits to reduce excessive extension cord usage (fire code) | |||
* left/west storage: put bulb covers over the 2x 4' flourescents | |||
* left/west storage: put bulb covers over the 2x 4' flourescents in annex/closet | |||
* left/west storage: replace ballast in flourescent fixture in this room | |||
* right/east storage: cover exposed octogon junction box in ceiling with appropriate octogon plate | |||
* right/east storage: replace exposed wiring from new LED fixture to ceiling with armored flex or EMT | |||
== Front Balcony == | |||
* 4'x2' light fixture panel cover | |||
* install paper towel dispenser and paper towels | |||
* bathroom: Replace light fixture (sub-8') with standard caged bell-jar type | |||
* between fridges: Lock roofer's ladder (that lives b/t fridges in balcony) to wall. | |||
* kitchenette: replace CFL bulb in kitchen with 'safe' LED (silicone-wrapped kind) spot shape - e.g. for food safety if CFL breaks | |||
* ~6" high barrier along balcony (to stop drinks etc from being knocked off onto those in cafe) | |||
=== TIL === | |||
* cover exposed wires in east wall (near bookshelf). can use a plate | * cover exposed wires in east wall (near bookshelf). can use a plate | ||
* get clear cover to put over wall switch for old electric timer in wall in big bookshelf unit in south wall of TL | * get clear cover to put over wall switch for old electric timer in wall in big bookshelf unit in south wall of TL |
Revision as of 16:50, 22 August 2015
stuff in the building to fix
Top Priority
Ballroom Area
- stage left: install paper towel dispenser and paper towels
Bar
- soffet-mounted ceiling light fixtures need: lightbulbs tested / replaced if necc
- Put up ABC signage req. for pub or private parties w/ alcohol re: cancer/pregnancy warning
- Outlets on east/shattuck-side wall need to be: removed, wire-nutted, wrapped in elec tape, covered with blank faceplates. TURN OFF CIRCUIT FIRST. Note: furthest N outlet not disconnected, only outlet in the center of the wall
Ballroom-Shattuck Exit Area
- install closers to both inner doors.
- install panic bars to both inner doors.
- install panic bars to both outer doors.
- install light cover into flourescent panel (22"x3') - flourescents are 2x 2' bulbs
Mezzanine
- SW staircase up: Repair hole in south wall near floor immediately across from stairs (see south wall acoustic treatment)
Mezzanine Bathroom
- outlet needs to be replaced with GFCI - Note: no ground; Gerald suggests decommissioning and installing new grounded plug in wall just above counter; go into wall from other side, need to locate grounded location
- all exposed bulb fixtures need be replaced with covered fixtures (2x)
Mezzanine "Book Room"
- 4"x4" Outlets affixed to top of Electrical subpanel must be removed from subpanel, and affixed to balcony (code violation) (3x)
Crow's Nest
- Clear everything 3' in front of electrical subpanel including all cords, lighitng, etc
- acquire & install cover for light (fixture takes glass orb / cover around bulb, it is missing)
- extend balcony railing to out in front of balcony hatch - on E side of R&J balcony (building & osha safety)
Ticketbooth Room
- Remove giant bookshelf and all debris/material from this room. Call Emerson - ask them to get their table back, or are they donating to us ? :)
- Patch small hole in ceiling corner above ticket window where new conduit was run.
Blue Room
- Install closer to Blue Room door that opens onto hallway
- Install closer to Blue Room door that opens onto Ballroom Bar
Disco Room
- light switch cover near 48th street door should be replaced by one with less-sharp edges (better-sized)
- weight load for high triangular shelves in corners to be assessed (julia) to determine if speakers etc can be placed there
- giant lateral file cabinet needs to be removed / find a better home somewhere JOHN GIVENS TO REMOVE - email photo
- Trace & label ALL elec outlets in this room
- A/V instructions need to be made for home stereo / speaker setup, mixer in crows nest etc. in this room
- West exit door (top landing to 48th st staircase) needs be panic bar'd
- install closer to main (east) door of disco room
- install closer to west / emergency exit door of disco room
- remove or permanently mount ALL LARGE UNMOUNTED PLATE GLASS MIRRORS in this room: safety hazard
- hole in wall in west staircase down to 48th needs be covered
- plate to be installed to cover exposed ceiling wires immediately in front of 48th st street door leading up to disco room
- crow's nest: giant hole in crows nest west wall needs to be a) filled with insulation b) covered (drywall etc)
- crow's nest west wall: exposed electrical wires / fixture needs to be covered (and traced)
La Commune
- install closer to basement stairs door
- replace all low uncover lights near entrance w cover lights x3
- locked storage - unplug and store all extension cords
Rise Above
- replace locking main door to Rise Above in hallway with twenty minute solid-core (fire-code)
- replace 2x hollow-core sliding doors with 20 minutes solid-core sliding doors (fire-code)
- replaced busted circuit breaker in every electrial panel (like in the 42 breaker panel) with either working breaker or factory blanks.
- put closer on main door to Rise Above
- remove 2x6 on ceiling on south side of room (COORDINATE WITH GABRIELA 1ST - move or cover all her stuff.
- stage left - install paper towel dispenser and paper towels.
Bocce Room
- hallway: install paper towel dispenser and paper towels
- entire room perimeter - 5LB ABC fire extinguishers at correct height every ~75' - starting w under each exit sign
- hallway door - install panic hardware & lock to this door
- hallway door - install closer to door
Sudo
- created dedicated space for storing excess lumber (long pieces), pipe, metal pieces, etc so they are not in jumbles (fire code).
- west wall - run more 3/4" conduit further down west wall. Must know code.
- ballroom door - put closer on this door
- basement door - if possible, put closer on this door (may not be possible)
CCL
- run new conduit / circuits to reduce excessive extension cord usage (fire code)
- left/west storage: put bulb covers over the 2x 4' flourescents
- left/west storage: put bulb covers over the 2x 4' flourescents in annex/closet
- left/west storage: replace ballast in flourescent fixture in this room
- right/east storage: cover exposed octogon junction box in ceiling with appropriate octogon plate
- right/east storage: replace exposed wiring from new LED fixture to ceiling with armored flex or EMT
Front Balcony
- 4'x2' light fixture panel cover
- install paper towel dispenser and paper towels
- bathroom: Replace light fixture (sub-8') with standard caged bell-jar type
- between fridges: Lock roofer's ladder (that lives b/t fridges in balcony) to wall.
- kitchenette: replace CFL bulb in kitchen with 'safe' LED (silicone-wrapped kind) spot shape - e.g. for food safety if CFL breaks
- ~6" high barrier along balcony (to stop drinks etc from being knocked off onto those in cafe)
TIL
- cover exposed wires in east wall (near bookshelf). can use a plate
- get clear cover to put over wall switch for old electric timer in wall in big bookshelf unit in south wall of TL
Basement
- south wall: close holes in basement wall where opened to remove mold.
- identify stuff in bunker rooms & hallway: what is Phat Beets, Black Holes, what is junk/unclaimed?
- Phat Beets room ventilation doesn't work. people can suffocate in there.
ceiling
- Acquire & install light fixture covers for the 4' flourescent fixtures in basement offices (bunker rooms) - roughly ~48"x16".
- install protective bulb covers over remaining working 8' flourescents: 6x
- unscrew piece of broken lightbulb from East basement hallway, replace bare-bulb fixture with covered fixture
- re-attach and restore service to entire strip of 8' flourescents along west wall (closest to sudo) that had been decommissioned
- acquire and affix 1'x1' ceiling tiles in NW corner of basement, so lighting fixture & strip of lights can be re-connected. ~120 tiles
- Cut & attach drywall AND then also affix 1'x1' ceiling tiles to exposed ceiling areas in basement (2 areas)
- Replace bad ballast in any 8' flourescent fixture (that is not turning on. If not sure try lights in it that do work in another fixture.
kitchen
- Purchase and affix Class-K extinguisher at correct height
- Cover exposed wiring in FNB locked-pantry ceiling (with e.g. metal plate)
- Install Ansul fire-suppression in hood
- Replace entire 4' flourescent light fixture closest to stove (has 1x broken tube holder)
- Acquire makeup air into kitchen (remove desk fan from duct, replace with something to code - 95% of hood CFM)
- Put closers on both basement kitchen doors
- steam clean stove hood
Medium Priority
Ballroom Area
Bar
- Determine fix for leaking sink in 3-sink (weld?) - southmost sink (on left if you are behind bar)
- Install floor sink under 3-sink as per health code
Ticketbooth Room
- Install closer to Ticketbooth room door (pref. good kind with long close time for wheelchair)
- install new outlet (existing is cracked and not attached to wall
A/V Room
- Patch small hole above door where conduit is peeking through.
- Patch hole near floor in NW corner of this room near door jamb. <--In progress by kkr
Mezzanine
- SE staircase: Install new led strip lighting on ea. side of stair to replace dead lighting strips
- SW staircase up: motion detector installed onto light fixture.
- SW staircase down: motion detector installed onto light fixture.
- SW staircase up: Install new led strip lighting on ea. side of stair to replace dead lighting strips
- SW staircase up: Determination if 3-way switch needs to be installed at top of stair. Currently there is only a switch at bottom landing.
Crow's Nest
- Refinish & airgap-seal east wall above loft in this room so room functions as soundproofing / air barrier to exterior of bldg
- Install real doorknob, remove latch
- make north door to romeo & juliet balcony airtight (or better fitting) for turning this room into a soundproofing barrier
- Install closer to main (east) door
- Install closer to north / balcony door
- ensure balcony hatch is robust enough to support 300lb standing weight
Mezzanine "Book Room"
- Electrical subpanel needs be moved to plywood wall south of panel, onto drywall, 2' from ground.
- 3-way switch wiring (for chandelier) inside subpanel needs to be removed and placed elsewhere as not ok in-panel.
- Install closer to Mezzanine room door
Basement Area
- west wall: re-connect or newly connect toggle switch to basement ventilation fan in basement. Currently breakers turn it on.
kitchen
- Resurface kitchen floor, cover with quarry tile
- Fix or replace corroded window frames along shattuck
- Cut in mop sink in westmost pantry area
- Acquire and install tankless water heater, check gas line diameter & exhaust ductwork
Cafe Balcony
bathroom
- Install closer to bathroom door.
kitchenette
- remove outlets & install blank plate in 4xoutlet area underneath counter on north side, near doorway
shower room
- Rekey/install lock to balcony shower room
- Install closer to shower room door
Bocce Room
- left (west) CCL storage: make plywood plate to cover / inset over exposed ejector pump sticking out under wall
Disco Room
- 4th window from main door as a broken pane
- 5th window from main door the window frame rub against the wall on E side
La Commune
- cover floor sink behind front counter area w minimum 3/4" plywood cut out and sealant (trip hazard/health)
- fix broken glass pane in 4th window west of front door in La Commune
- take out and cap OR at least cover w small platform the copper water lines along floor behind the front counter
Bottom Priority
Ballroom Area
Crow's Nest
- Make main (east) door to this room better fitting / gasketed against all air gaps so it functions for soundproofing
- rebalance fan
Mezzanine Bathroom
- active ventilation needs to be wired & installed (exhaust) in current ventilation window
Stage
- Create wider storage openings under stage. Not insubstantial. See stage storage build plan.
Ticketbooth Room
- Install threshold plate to base of jamb (no more than 1/2" high as per ADA) to cut down on sound from ballroom
- install gaskets to door jambs to cut down on sound. (icarus)
Mezzanine Bathroom
- install door stop so the door can be propped open sometimes.
Basement Area
Kitchen
- Knock out / expand west kitchen wall to next-west supporting pipe
- Remove firred-out drywall, cover with FRP
Cafe Balcony
- between fridges: get an exterior outlet plastic cover for 4"x4" outlet box here, so outlets do not get wet if it rains when roof hatch is open
- closet between fridges: install lock to this door, make lost & found room
bathroom
- Install ventilation exhaust fan in cafe balcony bathroom ceiling
kitchenette
- acquire and cable-lock to wall electric kettle; remove all stovetop kettles.
- replace gas stove with induction model (its a sklinny stove, keep eye peeled at urban ore H4H etc)
- replace stove exhaust fan with one that will exhaust air directly up through cabinets (in a duct) to above kitchen
TIL
- Get clear cover to put over wall switch for old electric timer in wall in big bookshelf unit in south wall of TIL
Disco Room
- test linoleum for asbestos content
- remove linoleum (may need to hire certified abatement company if asbestos present)
- sand wood floor and seal with water based polyurethane
- all A/V & musical equipment (including in crow's nest) needs to be recorded (serial #s) and ownership determined
- ensure remaining shelving along north wall of disco room is fixed/affixed more safely
- pendant lights should probably be raised a bit higher up (low priority)
- pendant light switch(es): consider replacing with dimmers
- lightswitch cover near 48th st door should be replaced with one with less-sharp edges (better-sized)
- weight load for high-up triangular shelves in corners to be assessed (julia) to determine if speakers etc can be placed there
Bocce Room
- do better job of affixing & routing low-voltage 'inside wiring' ie all ethernet, phone cabling
Sudo
- sand down side of basement door so it does not stick closed so bad (belt sander optimal)